Seeing AUX on your thermostat does not automatically mean your heat pump is broken. The useful question is what the control is asking your particular system to do, and whether your rooms are staying comfortable.
Emergency Heat is a different decision from an automatic AUX indication. Before changing either setting, identify your thermostat, outdoor unit, and backup heat source so you are following the right instructions.
Start with the equipment you actually own
A ducted heat pump may have electric resistance heaters inside its air handler, or it may share heating duties with a fuel-burning furnace. A ductless installation can have a different arrangement, and the absence of a familiar AUX label does not tell you everything about its controls.
Take photographs of the model labels from a safe, accessible position without removing a panel. Save the thermostat's exact model number as well, because a similar-looking replacement can have different menu names and supported equipment.
Your installation paperwork should explain the backup source and the contractor's control strategy. If it does not, ask the servicing contractor to identify those items before you rely on advice intended for another kind of system.
A room temperature, an outdoor temperature, and a thermostat message are three separate observations. Keep them together in your notes instead of treating a single display word as a complete diagnosis.

What automatic auxiliary heat is doing
Auxiliary heat is backup or supplemental heat called by the control system. Trane's explanation distinguishes that automatic call from the manually selected Emergency Heat setting, while describing electric heat strips and dual-fuel backup as different arrangements. (Trane: Auxiliary heat and emergency heat)
That distinction matters when you hear that AUX is expensive. Electric resistance backup and a gas furnace do not have the same fuel price, operating behavior, or relationship with the compressor, so a universal cost claim would hide the information you need.
A system may call for additional heat while recovering from a temperature change, during conditions its controls associate with high heating demand, or during defrost. Your specific control sequence belongs in the thermostat and equipment instructions rather than in a rule based on one outdoor temperature. (CEE: Living with an air-source heat pump)
Think about a cold morning after a large overnight setback. The thermostat is trying to recover your requested temperature, which may create a different demand from holding the same setting through the night.
What Emergency Heat changes
On the heat-pump thermostat arrangement described by Trane, manually selecting Emergency Heat locks out the heat pump and makes backup heat the heating source. That setting is intended for a failed heat pump requiring service, rather than a routine shortcut to make the room warm faster. (Trane: Auxiliary heat and emergency heat)
Do not assume every control uses precisely the same button, wording, or return procedure. Read the operating instructions for your thermostat, and ask your contractor to explain the appropriate action for your installed system.
If you were told to use emergency operation while waiting for a repair, write down who gave that instruction and why. Ask when to return to normal heating, how to recognize inadequate heating, and what to do if the backup system also stops working.
Do not disable a backup source, change installer lockouts, or disconnect wiring to make an indicator disappear. Those actions can remove a planned protection while leaving the original problem unresolved.
Compare a normal event with a persistent problem
A short indication during a known recovery event deserves a different conversation from a house that keeps getting colder. Note whether the requested temperature is eventually reached, whether the behavior is new, and whether the same conditions previously felt comfortable.
A thermostat history screen can help you describe timing when your model provides one. It is still a control record, not an independent measurement of delivered heat or proof of a refrigerant problem.
From outside, you can observe whether snow or debris is visibly obstructing the equipment without reaching into it. Keep away from moving parts, sharp coil fins, electrical connections, and anything that would require climbing or opening the cabinet.
Frost or a change in sound can have more than one explanation. A photograph with a time stamp is more useful to a technician than repeatedly switching modes to see whether the equipment behaves differently.
Keep a brief service log
Make one note when you first notice the issue, then another after a reasonable observation period if the home remains safely warm. Include the room temperature, set temperature, thermostat message, approximate outdoor conditions, and whether you changed the schedule.
Describe a sound in ordinary language and say where you hear it. You do not need to decide whether it is a compressor, fan motor, or valve before asking for service.
Record any recent work, thermostat replacement, electrical outage, or new schedule. A change that started immediately after another change is useful context, even when it does not establish the cause.
If you use a dual-fuel system, mention which fuel-burning equipment is installed. Do not infer that the furnace is operating correctly just because you can hear air moving through the registers.
Make settings changes deliberately
Use the comfort schedule your installer recommends for the heat pump and thermostat combination. If large temperature recoveries repeatedly coincide with AUX, ask whether the control has a supported recovery strategy that better fits your routine.
Change one ordinary user setting at a time and keep a record. Altering a schedule, fan mode, and set temperature together makes it harder to see which change affected comfort.
Avoid choosing a lower indoor temperature simply to force a warning off when someone in the home needs more warmth. A control message is less important than maintaining a safe, livable indoor environment while you arrange an appropriate response.
The right question for a service visit is whether the controls and equipment follow the intended sequence. Ask the technician to explain the observation behind any proposed adjustment instead of accepting a setting change with no explanation.
Know when observation should stop
If you notice smoke, a burning odor, electrical arcing, or another immediate danger, stop troubleshooting and follow the appropriate emergency response. Do not remove panels, test live wiring, repeatedly reset a tripping breaker, or use the thermostat as a substitute for professional help.
If your home cannot maintain a safe temperature, make a plan for the people and pets inside while arranging service. Keep any temporary heater use within its instructions and never improvise combustion heating indoors.
For a nonurgent service request, send the model information and your short log through the provider's normal channel. That gives the technician a clearer starting point than a request to simply turn AUX off.
Leave with an operating explanation
After a repair or control adjustment, ask what normal operation should look like on your display. Have the contractor show you the ordinary heating mode, any backup indication, and the circumstances in which you should call again.
Keep that explanation with the manuals and service record. You can then respond to the next unfamiliar thermostat message with the facts of your own installation rather than a generic temperature rule.
If you have just moved into the house
Ask for a heating-control handover instead of guessing from the previous owner's preferred temperature. Find out who installed or serviced the equipment, where the operating instructions are, and which backup source is connected.
If the old paperwork is incomplete, give a qualified provider the equipment and thermostat model numbers. A clear explanation of the existing setup is more valuable than copying a neighbor's settings, even when both houses have heat pumps.