Honeywell Thermostat Auxiliary Heat: Guide to Efficient Heat Pump Heating

An earlier article from Heat Pump Prices Reviews.

In this guide
  1. What Is Auxiliary Heat On A Honeywell Thermostat
  2. How Auxiliary Heat Works With Heat Pumps
  3. Common Configurations And Settings On Honeywell Models
  4. Tips For Efficient Use Of Auxiliary Heat
  5. Troubleshooting Common Issues

The term auxiliary heat on a Honeywell thermostat refers to the secondary heat source that activates when the primary heat pump system cannot meet the desired indoor temperature efficiently. This guide explains what auxiliary heat is, how it works with Honeywell models, common configurations, how to optimize settings for comfort and efficiency, and troubleshooting steps for typical issues. Understanding auxiliary heat helps homeowners reduce energy use, maintain consistent comfort, and avoid excessive utility costs.

What Is Auxiliary Heat On A Honeywell Thermostat

Auxiliary heat, sometimes called emergency heat on some Honeywell thermostats, is a supplemental heating source used by heat pump systems. When outdoor temperatures are extremely low or the heat pump struggles to extract enough warmth, the auxiliary system—often electric resistance coils—kicks in to maintain indoor comfort. On Honeywell thermostats, this mode is designed to operate only when necessary, and it is generally less efficient than the heat pump’s primary operation. Recognizing when auxiliary heat is active helps users monitor energy use and identify potential issues with the heat pump that might be causing excessive reliance on auxiliary heat.

How Auxiliary Heat Works With Heat Pumps

Heat pumps transfer heat from outside to inside, but their efficiency drops as outdoor temperatures fall. Auxiliary heat provides a reliable backup to ensure consistent temperatures. On most Honeywell models, the thermostat monitors indoor and outdoor temperatures and energy needs, triggering auxiliary heat when the heat pump alone cannot reach the setpoint quickly. This results in higher energy consumption per hour but prevents uncomfortable temperature swings. Understanding the interaction between the heat pump and auxiliary heat helps homeowners set reasonable temperature targets and avoid overusing auxiliary heat during mild days.

Key dynamics include:

  • Activation Criteria: Auxiliary heat engages when the thermostat cannot meet the demand within a short time frame, or when the heat pump’s efficiency drops below a configured threshold.
  • Defrost Cycles: In some climates, defrost cycles may temporarily affect heat pump performance, prompting brief auxiliary heat use.
  • Stage Control: Some Honeywell models support two stages of heat (Stage 1 heat pump, Stage 2 auxiliary), while newer or higher-end models may combine variables to optimize efficiency.
  • Energy Implications: Electric auxiliary heat typically uses higher wattage than the heat pump, so prolonged reliance increases electricity usage.

Common Configurations And Settings On Honeywell Models

Honeywell offers a range of thermostats—basic, programmable, and smart models—that manage auxiliary heat in slightly different ways. Understanding your model helps optimize performance and energy use.

  • Two-Stage Systems: In two-stage configurations, the heat pump handles primary heating while auxiliary heat provides a second stage when needed. The thermostat may display “Aux” or “Auxiliary” when engaged.
  • Smart Thermostats: Models like the Honeywell Home or Honeywell Lyric series monitor humidity, outdoor temperature, and occupancy to modulate auxiliary heat more intelligently, reducing unnecessary usage.
  • Defrost And Self-Check Features: Some units perform automatic self-checks and defrost cycles, which can temporarily trigger auxiliary heat during transitions.
  • Settings To Review: Look for settings such as “Heat Type,” “Auxiliary Heat Enable/Disable,” “Aux Heat Delay,” and “Energy Saving Mode.” Adjusting these can impact when and how auxiliary heat activates.

Tip: Always consult the specific model’s user manual for exact terminology and navigation paths, as menus may vary between legacy and current versions of Honeywell thermostats.

Call 877-693-2753 – Free Local HVAC Quotes. Compare & Save Today!

Tips For Efficient Use Of Auxiliary Heat

Efficient use of auxiliary heat can save energy and reduce costs while maintaining comfort. Consider the following best practices:

  • Optimize Setpoints: Set the thermostat to a comfortable target that minimizes the frequency of auxiliary heat activation. A modest setback at night can reduce overall energy use.
  • Regular Heat Pump Maintenance: Clean filters, ensure proper refrigerant levels, and schedule annual professional maintenance. A well-tuned heat pump runs more efficiently, decreasing reliance on auxiliary heat.
  • Programmable Schedules: Use a schedule that aligns with occupancy and outdoor temperatures. Flip to higher efficiency modes during milder days when auxiliary heat is less necessary.
  • Utilize Auxiliary Heat Strategically: In milder winter conditions, allow the heat pump to do most of the work and limit auxiliary heat to brief comfort adjustments rather than continuous operation.
  • Outdoor Temperature Considerations: In very cold climates, expect higher auxiliary heat usage and plan for higher energy costs during those periods.
  • Insulation And Air Leaks: Improve home sealing and insulation to reduce heat loss, which lowers the frequency of auxiliary heat engagement.

Troubleshooting Common Issues

Several scenarios may cause extended reliance on auxiliary heat or unexpected activation. The following are common issues and practical steps to address them:

  • Auxiliary Heat Stays On Too Long: Check thermostat settings for improper fan or hold settings, verify that the outdoor temperature sensor is accurate, and ensure no recent thermostat recalibrations have altered thresholds. If the issue persists, professional service may be required to inspect the heat pump’s refrigerant charge and compressor performance.
  • Auxiliary Heat Never Activates When Needed: This may indicate a failing heat pump, a faulty reversing valve, or an incorrect thermostat configuration. Inspect the thermostat wiring and test mode operations in user manuals. If the problem remains, contact a licensed HVAC technician.
  • Inaccurate Temperature Readings: Poor sensor placement or dirty air filters can skew readings. Ensure sensors are positioned away from direct sun, drafts, or heat sources and replace filters regularly for accurate thermostat feedback.
  • Defrost Cycles Impacting Comfort: Defrost cycles can temporarily reduce heat pump output, triggering short auxiliary heat bursts. This is normal, but repeated, lengthy cycles warrant a system check to ensure proper defrost operation and refrigerant integrity.

When troubleshooting, document observed patterns—time of day, outdoor temperature, and indoor comfort levels—and share them with an HVAC professional to speed diagnostics.